Reference
MVI69L-MBS ♦ Platform
User Manual
Modbus Serial Lite Communication Module
Page 112 of 130
ProSoft Technology, Inc.
7.4.7 Get Event with Data Status Block (8100)
Block 8100: Get Event with Data Status
This block requests status data for Event with Data Commands.
Block 8100: Request from Processor to Module
Offset
Description
0
Write Block ID: 8100 status data request for Event with Data Commands.
1 to 239
Spare
Block 8100: Response from Module to Processor
Offset
Description
0
Read Block ID: 8100 status data for Event with Data Commands.
1
Write Block ID: To be used by the processor in its next Write block.
2
Event command status for Port 1:
0=No message active
1=Waiting to execute command
2=Command complete
3
Error code for last command executed for Port 1
6 to 239
Spare
7.4.8 Get Configuration File Information Block (9000 or -9000)
Block 9000 or -9000: Get Configuration File Information
This block requests information from the processor about the configuration file, in
preparation for transferring the configuration file from the processor to the
module. It specifies the location in the configuration file to start copying and
sending the information.
Block 9000 or -9000: Request from Module to Processor
Offset
Description
0
Read Block ID: 9000 or -9000 request for configuration file information from processor
1
Write Block ID: 9000 or -9000 to be used by the processor in its next Write block.