101501-565 Rev C
Page 49 of 58
6.6.11 Request Unit Scaling
Description:
The host requests that the firmware send the full scale range values.
Direction:
Host to supply
Syntax:
<STX><28><,><CSUM><ETX>
Response:
If an error is detected, the Power Supply responds with:
<STX>28,!,<ERROR>,<ETX>
Please reference the Error Code section for a list of valid error codes.
If the message is accepted, the Power Supply responds with:
<STX>28,<ARG1>,<ARG2>,<CSUM><ETX>
Where:
<ARG1> = Full Scale kV Value
<ARG2> = Full Scale mA Value
Example Response:
For a 100kV/1000mA power supply
<STX>28,100,1000,<CSUM><ETX>