13.3.5 AFE
Class
Subclass
Name
Type
Min
Max
Default
Description
Configuration
AFE
AFE Protection
Control
H1
0x00
0xFF
0x00
Bit 0: RSNS—AOLD, ASCC, ASCD1, ASCD2 Thresholds
0 = 0.5 × AFE Protection Thresholds (default)
1 = Normal AFE Protection Thresholds
Bit 1: SCDDx2—Double SCD Delay Times
0 = Normal SCD delay times (default)
1 = 2 × SCD delay times
Bits 2–3: Reserved
Bit 4–7: RSTRIM—"Unsupport" function. Should leave the default
setting 0x7. Changing this setting may cause an error to the AFE
current protection accuracy.
Configuration
AFE
ZVCHG Exit
Threshold
I2
0
8000
2200
Voltage()
threshold in mV when the gauge will exit ZVCHG mode
when CFET is used for precharging.
13.3.6 Manufacturing
Class
Subclass
Name
Type
Min
Max
Default
Description
Settings
Manufacturing
Manufacturing Status
H2
0x0000
0xFFFF
0x0000
Bit 0: Reserved
Bit 1: Reserved
Bit 2: Reserved
Bit 3: GAUGE_EN—Gauging
0 = Disabled (default)
1 = Enabled
Bit 4: FET_EN—FET action
0 = Disabled (default)
1 = Enabled
Bit 5: LF_EN—Lifetime data collection
0 = Disabled (default)
1 = Enabled
Bit 6: PF_EN—Permanent failure
0 = Disabled (default)
1 = Enabled
Bit 15:7: Reserved
13.4 Advanced Charging Algorithms
13.4.1 Temperature Ranges
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Advanced
Charging
Algorithms
Temperature
Ranges
T1
I1
–128
127
0
°C
T1 low temperature range lower limit
Advanced
Charging
Algorithms
Temperature
Ranges
T2
I1
–128
127
12
°C
T2 low temperature range to standard temperature
range
Advanced
Charging
Algorithms
Temperature
Ranges
T5
I1
–128
127
20
°C
T5 recommended temperature range lower limit
Advanced
Charging
Algorithms
Temperature
Ranges
T6
I1
–128
127
25
°C
T6 recommended temperature range upper limit
Advanced
Charging
Algorithms
Temperature
Ranges
T3
I1
–128
127
30
°C
T3 standard temperature range to high temperature
range
Advanced
Charging
Algorithms
Temperature
Ranges
T4
I1
–128
127
55
°C
T4 high temperature range upper limit
Advanced
Charging
Algorithms
Temperature
Ranges
Hysteresis
I1
–128
127
1
°C
Temperature Hysteresis, applied when temperature is
decreasing.
13.4.2 Low Temp Charging
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Advanced
Charging
Algorithms
Low Temp
Charging
Voltage
I2
0
32767
4000
mV
Low temperature range
ChargingVoltage()
Advanced
Charging
Algorithms
Low Temp
Charging
Current Low
I2
0
32767
132
mA
Low temperature range low voltage range
ChargingCurrent()
Data Flash Values
102
BQ28Z610-R2
Copyright © 2022 Texas Instruments Incorporated