1 = Active
0 = Inactive
CB (Bit 28)
: Cell Balancing
1 = Active
0 = Inactive
SLPCC (Bit 27)
: CC measurement in SLEEP mode
1 = Active
0 = Inactive
SLPAD (Bit 26)
: ADC measurement in SLEEP mode
1 = Active
0 = Inactive
SMBLCAL (Bit 25)
: Auto-offset calibration when bus low is detected.
1 = Active
0 = Inactive
INIT (Bit 24)
: Initialization after full reset
1 = Active
0 = Inactive
SLEEPM (Bit 23)
: SLEEP mode
1 = Active
0 = Inactive
XL (Bit 22)
: 400-kHz mode
1 = Active
0 = Inactive
CAL_OFFSET (Bit 21)
: Calibration Output (raw
CC Offset
data)
1 = Active when MAC
OutputShortedCCADCCal()
is sent and the raw shorted CC data for calibration is available.
0 = When the raw shorted CC data for calibration is not available.
CAL (Bit 20)
: Calibration Output (raw ADC and CC data)
1 = Active when either the MAC
OutputCCADCCal()
or
OutputShortedCCADCCal()
is sent and the raw CC and ADC data for
calibration is available.
0 = When the raw CC and ADC data for calibration is not available.
AUTHCALM (Bit 19)
: Auto CC Offset Calibration by MAC
AutoCCOffset()
1 = The gauge receives the MAC
AutoCCOffset()
and starts the auto CC Offset calibration.
0 = Clear when the calibration is completed.
AUTH (Bit 18)
: Authentication in progress
1 = Active
0 = Inactive
RSVD (Bit 17)
: Reserved
SDM (Bit 16)
: SHUTDOWN triggered through a command
1 = Active
0 = Inactive
SLEEP (Bit 15)
: SLEEP mode conditions met
1 = Active
0 = Inactive
SEC1, SEC0 (Bits 14, 13):
SECURITY mode
I2C Commands
SLUUCO0 – APRIL 2022
BQ28Z610-R2
83