T1
T2
T5
T6
T3
T4
Under Temp
ChargingStatus() [ UT]
= 1
Low Temp
ChargingStatus() [ LT]
= 1
Standard Temp Low
ChargingStatus() [ STL]
= 1
Standard Temp High
ChargingStatus() [STH]
= 1
Recommended Temp
ChargingStatus() [ RT]
= 1
High Temp
ChargingStatus() [ HT]
= 1
Over Temp
ChargingStatus() [OT]
= 1
Temperature()
Temperature()
>
T1
+
Hysteresis Temp
Temperature()
>
T2
+
Hysteresis Temp
Temperature()
>
T5
+
Hysteresis Temp
Temperature()
>
T6
Temperature()
>
T3
Temperature()
>
T4
Temperature()
<
T1
Temperature()
<
Temperature()
<
T 5
Temperature()
<
T6
±
Hysteresis Temp
Temperature()
<
T3
±
Hysteresis Temp
Temperature()
<
T4
±
Hysteresis Temp
T2
4.3 Voltage Range
The measured cell voltage is segmented into several voltage ranges. The charging algorithm adjusts
ChargingCurrent()
according to the temperature range and voltage range. The voltage ranges set in data flash
should adhere to the following format:
Charging Voltage Low ≤ Charging Voltage Med ≤ Charging Voltage High ≤ × Temp Charging:Voltage
where x is Standard or Rec. Depending on the specific charging profile, the
Low Temp Charging:Voltage
and
High Temp Charging:Voltage
settings do not necessarily have the highest setting values.
Charging Voltage
Low
Cell Voltage
Charging Voltage
Medium
Charging Voltage
High
Precharge State
ChargingStatus()[PV]
= 1
Low Voltage State
ChargingStatus()[LV]
= 1
Medium Voltage State
ChargingStatus()[MV]
= 1
High Voltage State
ChargingStatus()[HV]
= 1
Not Charging
AND
Max Cell Voltage 1...2 <
Charging Voltage High
–
Charging Voltage Hysteresis
Not Charging
AND
Max Cell Voltage 1...2 <
Charging Voltage Medium
–
Charging Voltage Hysteresis
At any non pre
-
charge state,
If Min Cell Voltage <
Precharge Start Voltage
Max Cell Voltage 1...2 >
Charging Voltage Low
Max Cell Voltage 1...2 >
Charging Voltage Medium
Max Cell Voltage 1...2 >
Charging Voltage High
Not Charging
AND
Max Cell Voltage 1...2 <
Charging Voltage Low
–
Charging Voltage Hysteresis
4.4 Charging Current
The
ChargingCurrent()
value changes depending on the detected temperature and voltage per the charging
algorithm.
Advanced Charge Algorithm
24
BQ28Z610-R2
Copyright © 2022 Texas Instruments Incorporated