Status
Condition
Action
Activate
0x0070 to
MACSubcmd()
Outputs 32 bytes of ManufacturerInfo on
MACData()
in
the following format: AABBCCDDEEFFGGHHIIJJKKLLMMNN
OOPPQQRRSSTTUUVVWWXXVVZZ112233 445566
12.2.37 MACSubcmd() 0x0071 DAStatus1
This command returns the CellVoltages, PackVoltage, BatVoltage, CellCurrents, CellPowers, Power, and
AveragePower on
MACData()
.
Status
Condition
Action
Activate
0x0071 to
MACSubcmd()
Outputs 32 bytes of data on
MACData()
in the following format:
aaAAbbBBccCCddDDeeEEffFFggGGhhHHiiIIjjJJkkKKllLLmmMMnn
NNooOOppPP where:
AAaa: Cell Voltage 1
BBbb: Cell Voltage 2
CCcc:
DDdd:
EEee: BAT Voltage. Voltage at the VC2 (BAT) terminal
FFff: PACK Voltage
GGgg: Cell Current 1. Simultaneous current measured during Cell
Voltage1 measurement
HHhh: Cell Current 2. Simultaneous current measured during Cell
Voltage2 measurement
IIii:
JJjj:
KKkk: Cell Power 1. Calculated using Cell Voltage1 and Cell Current
1 data
LLll: Cell Power 2. Calculated using Cell Voltage2 and Cell Current 2
data
MMmm:
NNnn:
OOoo: Power calculated by
Voltage()
×
Current()
PPpp: Average Power. Calculated by
Voltage()
×
AverageCurrent()
12.2.38 MACSubcmd() 0x0072 DAStatus2
This command returns the internal temp sensor, TS1
MACData()
.
Status
Condition
Action
Activate
0x0072 to
MACSubcmd()
Outputs 14 bytes of temperature data values on
MacData()
in the
following format: aaAAbbBBccCCddDDeeEEffFFggGG where: AAaa:
Int Temperature
BBbb: TS1 Temperature
CCcc:
DDdd:
EEee:
FFff:
GGgg:
12.2.39 MACSubcmd() 0x0073 ITStatus1
This command instructs the device to return Impedance Track related gauging information on
MACData()
.
I2C Commands
SLUUCO0 – APRIL 2022
BQ28Z610-R2
89