3.3 Voltage Imbalance at Rest Permanent Fail
The device can permanently disable the battery pack in case of a voltage difference between the cells in a stack
while at rest.
Status
Condition
Action
Normal
CellVoltage0..1()
<
VIMR:Check Voltage
OR
|
Current()
| >
VIMR:Check Current
OR
Δ(
CellVoltage0..1()
) <
VIMR:Delta Threshold
PFAlert()[VIMR]
= 0
Alert
Any(
CellVoltage0..1()
) ≥
VIMR:Check Voltage
AND
|
Current()
| <
VIMR:Check Current
for
VIMR:Duration
AND
Δ(
CellVoltage0..1()
) ≥
VIMR:Delta Threshold
PFAlert()[VIMR]
= 1
Trip
Any(
CellVoltage0..1()
) ≥
VIMR:Check Voltage
AND
|
Current()
| <
VIMR:Check Current
for
VIMR:Duration
AND
Δ(
CellVoltage0..1()
) ≥
VIMR:Delta Threshold
for
VIMR:Delta
Delay
PFAlert()[VIMR]
= 0
PFStatus()[VIMR]
= 1
BatteryStatus()[TCA]
= 1
BatteryStatus()[TDA]
= 1
3.4 Voltage Imbalance Active Permanent Fail
The device can permanently disable the battery pack in case of a voltage difference between the cells in a stack
while active.
Status
Condition
Action
Normal
CellVoltage0..13()
<
VIMA:Check Voltage
OR
|
Current()
| <
VIMA:Check Current
OR
Δ(
CellVoltage0..1()
) <
VIMA:Delta Threshold
PFAlert()[VIMA]
= 0
Alert
Any(
CellVoltage0..1()
) ≥
VIMA:Check Voltage
AND
|
Current()
| >
VIMA:Check Current
for
VIMA: Duration
AND
Δ(
CellVoltage0..1()
) ≥
VIMA:Delta Threshold
PFAlert()[VIMA]
= 1
Trip
Any(
CellVoltage0..1()
) ≥
VIMA:Check Voltage
AND
|
Current()
| >
VIMA:Check Current
for
VIMA: Duration
AND
Δ(
CellVoltage0..1()
) ≥
VIMA:Delta Threshold
for
VIMA:Delay
PFAlert()[VIMA]
= 0
PFStatus()[VIMA]
= 1
BatteryStatus()[TCA]
= 1
BatteryStatus()[TDA]
= 1
3.5 Charge FET Permanent Failure
3.5.1 Description
The device will enter PERMANENT FAILURE mode in case the charge (CHG) FET is not working properly.
Status
Condition
Action
Normal
CHG FET off AND
Current()
<
CFET:OFF Threshold
PFAlert()[CFETF]
= 0
Alert
CHG FET off AND
Current()
≥
CFET:OFF Threshold
PFAlert()[CFETF]
= 1
Trip
CHG FET off AND
Current()
continuously ≥
CFET:OFF Threshold
for
CFET:OFF Delay
duration
PFAlert()[CFETF]
= 0
PFStatus()[CFETF]
= 1
Table 3-1. CFET Data Flash Configuration
Class
Subclass
Name
Type
Min Value
Max Value
Default
Value
Unit
Permanent Fail
CFET
OFF Threshold
I2
0
500
5
mA
Permanent Fail
CFET
Delay
U1
0
255
5
s
3.5.2 Feature Enable/Disable
The feature is enabled when
CFETF
is set in
Enable PF C
.
3.6 Discharge FET Permanent Failure
3.6.1 Description
The device will enter PERMANENT FAILURE mode in case the discharge (DSG) FET is not working properly.
Permanent Fail
20
BQ28Z610-R2
Copyright © 2022 Texas Instruments Incorporated