THCV242_ Rev.2.00_E
Copyright
©
2019 THine Electronics, Inc. THine Electronics, Inc.
43/53
Security E
As a register, interrupt detected state is “1” and cleared state is “0”. When multiple interrupt sources are
activated, the OR operated result is indicated as IC external INT1/0 pin output.
As an external INT1/0 pin output, open drain output interrupt detected state is “Low” and cleared state is “Hi-
Z”, while INT1/0 pin CMOS push-pull output interrupt detected state is “Low” and cleared state is “High”.
Table 32.
INT1/0 pin output control
INT1/0 interrupt function is supposed to be cleared before start monitoring any desired status because INT1/0
status may have been changed before monitoring activation.
Register Auto Checksum diagnosis
Register values checksum is continuously calculated as R_CKSUM_RVAL.
Table 33.
Register Auto Checksum diagnosis control and monitoring
bit
Register Name
width
R/W
init
Description
0x10 06
[7:4]
R_INT1_MODE
4
R/W
4'h0
INT1 I/O Mode
0:Disable
1:OpenDrain Output Mode
2:Push/Pull Output Mode
3~F:Reserved
0x10 06
[3:0]
R_INT0_MODE
4
R/W
4'h0
INT0 I/O Mode
0:Disable
1:OpenDrain Output Mode
2:Push/Pull Output Mode
3~F:Reserved
Adr
Addr(h)
bit
Register Name
width
R/W
Description
Default
0x0008
[7:1] reserved
7
-
-
-
[0]
R_CKSUM_EN
1
RW
Internal Register AutoCheckSum Enable
0:Disable
1:Enable
1'b0
0x0009
[7:0] R_CKSUM_TIM
8
RW
Internal Register AutoCheckSum check interval
=1024×64×(R_CKSUM_TIM<7:0>+1) × tOSC
8'd19
0x000A
[7:0] R_CKSUM_VAL
8
RW Internal Register AutoCheckSum expected target value
8'd0
0x000B
[7:0] R_CKSUM_RVAL
8
R
Internal Register AutoCheckSum read value
-