32
(
Note 3
)
If the input / output power units data is 0, the monitored data is in 0.01kW units, and the multiplier is
0.01. If the input / output power units data is 1, the monitored data is in 0.1kW units, and the multiplier
is 0.1. These values are automatically set according to the inverter’s capacity.
Table 4: Output Terminal Status Monitor (register 0D)
Lower
Byte
Bit Output
Terminal
0
1
Single-Bit
Read Mask
bit 0
unused (always 0)
bit 1
unused (always 0)
bit
2
FAN
OFF
ON
0004
bit 3
FL
FLB-FLC shorted
FLA-FLC shorted
0008
bit 4
MS relay
OFF
ON
0010
bit 5
OUT (option)
OUTB-OUTC shorted
OUTA-OUTC shorted
0020
bit 6
RCH
RCHA-RCHC open
RCHA-RCHC shorted
0040
bit 7
LOW
LOWA-LOWC open
LOWA-LOWC shorted
0080
Table 5: Inverter Status 1 (register 0E)
Lower
Byte
Bit Inverter
Status
0
1
Single-Bit
Read Mask
bit 0
running (acc/dec)
running 0001
bit 1
unused (always 0)
bit 2
forward / reverse
reverse
forward
0004
bit 3
acc/dec #1/#2
acc/dec #1
acc/dec #2
0008
bit 4
for inverter use
bit 5
for inverter use
bit 6
for inverter use
bit 7
jog/normal mode
normal (acc/dec)
jog mode
0080
Upper
Byte
Bit Inverter
Status
0
1
Single-Bit
Read Mask
bit 0
feedback ON/OFF
OFF
feedback active
0001
bit 1
DC inj. braking
OFF
DC inj. braking active
0002
bit 2
V/F #1/#2
V/F #1
V/F #2
0004
bit
3
coasting not
coasting coasting
0008
bit 4
emergency off
not in emergency off
in emergency off
0010
bit 5
for inverter use
bit 6
for inverter use
bit 7
for inverter use
Table 6 : Inverter Status 2 (register 0F)
Upper
Byte
Bit Inverter
Status
0
1
Single-Bit
Read Mask
bit
0
accelerating not
accelerating accelerating 0001
bit
1
decelerating not
decelerating decelerating 0002
bit 2
for inverter use
bit
3
retry
not
retrying
retrying
0008
bit 4
running (including DC
injection braking)
stopped running
0010
bit 5
for inverter use
bit 6
for inverter use
bit
7
tripped not
tripped tripped
0080