for regulation.
1: The output voltage is used for regulation.
Any signals at the sense connector are ignored.
Bit 4: Enable External Inhibit input.
0: The external inhibit input is ignored.
1: The external inhibit input must be connected to
a voltage source to allow switch on.
Bit 5: Disable Global Inhibit inputs.
0: The global inhibit/interlock inputs of the system is active.
1: The global inhibit/interlock inputs of the system is ignored.
Bit 6: Automatic Power On.
0: After switching the main system switch ON, the output is not
switched on automatically. A separate outputSwitch command is
required.
1: After switching the main system switch ON, the output is
switched on automatically. If 'Disable Global Inhibit' (bit 5)
is set, the output will be switched on regardless of the global
inhibit/interlock signals.
outputSupervisionBehavior OBJECT-TYPE
-- FROM WIENER-CRATE-MIB
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A bit field packed into an integer which define the behavior of the output channel /
power supply after failures.
For each supervision value, a two-bit field exists.
The enumeration of this value (..L+..H*2) is:
WIENER LV devices
0 ignore the failure
1 switch off this channel
2 switch off all channels with the same group number
3 switch off the complete crate.
iseg HV devices
0 ignore the failure
1 switch off this channel by ramp down the voltage
2 switch off this channel by a emergencyOff
3 switch off the whole board of the HV module by emergencyOff.
The position of the bit fields in the integer value are:
Bit 0, 1: outputFailureMinSenseVoltage
Bit 2, 3: outputFailureMaxSenseVoltage
30. May 2018
42