340
Chapter 5
Language Reference
SENSe Subsystem
Waveform (Time-Domain) Measurement
Commands for querying the waveform measurement results and for
setting to the default values are found in the
. The equivalent front panel keys for the
parameters described in the following commands, are found under the
Meas Setup
key, after the
Waveform (Time Domain)
measurement has
been selected from the
MEASURE
key menu.
Waveform—Data Acquisition Packing
[:SENSe]:WAVeform:ACQuistion:PACKing AUTO|LONG|MEDium|SHORt
[:SENSe]:WAVeform:ACQuistion:PACKing?
This is an advanced control that normally does not need to be changed.
Factory Preset
and *RST:
Auto
Remarks:
You must be in the Service mode to use this command.
Use INSTrument:SELect to set the mode.
Waveform—ADC Dither State
[:SENSe]:WAVeform:ADC:DITHer[:STATe] |OFF|ON|0|1
[:SENSe]:WAVeform:ADC:DITHer[:STATe]?
This is an Advanced control that normally does not need to be changed.
Factory Preset
and *RST:
Off
Remarks:
You must be in the Service mode to use this command.
Use INSTrument:SELect to set the mode.
Waveform—Pre-ADC Bandpass Filter
[:SENSe]:WAVeform:ADC:FILTer:[:STATe] OFF|ON|0|1
[:SENSe]:WAVeform:ADC:FILTer:[:STATe]?
Turn the pre-ADC bandpass filter on or off. This is an Advanced control
that normally does not need to be changed.
Preset:
Off
Remarks:
To use this command, the appropriate mode should be
selected with INSTrument:SELect.
Summary of Contents for E4406A VSA Series
Page 4: ...4 ...
Page 59: ...59 2 Programming Fundamentals ...
Page 124: ...124 Chapter2 Programming Fundamentals Using the LAN to Control the Analyzer ...
Page 125: ...125 3 Programming Examples ...
Page 164: ...164 Chapter3 Programming Examples Using Java Programming Over Socket LAN ...
Page 165: ...165 4 Programming Command Cross References ...
Page 379: ...379 6 Error Messages ...
Page 412: ...412 Chapter6 Error Messages Error Message Descriptions ...