© 2022 ANTZER TECH CO., LTD.
24
//Power Saving Mode: set the parameters of how to enter power saving code
AT+PWSV,< Power OFF Detect >,<Duration>
< Power OFF Detect >: 0: Disable, Bit 0: Motion OFF, Bit 1: Engine OFF, Bit 2: ACC OFF
<Duration>: Default 3min(minimum unit is 1 min), wait after <Power OFF Detect> conditions
are all detected, then enter into power saving.
//System Reset (only Write Cmd): reset and save parameters by this command
AT+RST,<Action>
<Mode>:
1: System Reboot
2: Save all parameters
3: Reset all parameters to factory default
4: Clear external flash memory
// Query firmware Version: check the firmware version by this command
AT+VER?
//Tracking Report Data: set up the frequency of tracking data
AT+TRCK,<Mode>,< Tracking interval >
<Mode>: 0: Disable Tracking Report Data, 1: Time Mode
< Tracking interval >: Default “30” seconds (minimum unit is 1sec)
//Set SIMCard PIN Code: key in the pin code of SIM card if needed
AT+PIN,<PIN Code>
<PIN Code>: Max Len 10 characters
//Set the vehicles virtual odometer: define the initial value of virtual odometer
AT+ODOM,<odom_value>
<odom_value>: set the virtual odometer initial value (Default value is 0 Kilometers)
The unit of virtual odometer value is in 0.1 kilometer (ex: value 12350 is equal to set 1235
km)