38
GSM/GPRS Alarm Communicators
Remote Activation and Deactivation of the Outputs
(BGSM-120 series only)
,
,
,
,
,
CAUTION - The GSM connection must be established before the outputs can be activated/deactivated
remotely.
The Open Collector outputs can be set as
Bistable
(activation and deactivation takes place by means of 2 separate
commands) or
Monostable
(the output remains active for the
ON time
and returns to standby mode when this period has
elapsed). Moreover, every output can be programmed to provide a confirmation signal (an SMS programmed previously
if output activation/deactivation is performed via SMS, or a confirmation ring if output activation/deactivation is performed
via caller identification).
,
,
,
,
,
For further information on the terms “Control string” and “User code” used in this section, please refer to
the “I/O” and “Options->Codes” sections of the “PROGRAMMING VIA PC” chapter.
Bistable outputs
Open collector outputs set as bistable can be activated in 2 ways:
1.
By sending an SMS consisting of the
User code
between two
#
characters, the
Control string
(
Control String
can not
have initial blank spaces) and the characters “
=ON#
”, as follows:
#User code#String=ON# (example: #9876#HOUSELIGHT=ON#)
2.
Through
caller identification
: in this case the output is activated at “cost-free” as the Communicator, after identifying the
caller, rejects the call and activates the output.
,
,
,
,
,
We recommend the device is programmed with the Black list enabled (Options->Dial Options) and White list
disabled (Phonebook->White list) for the numbers you wish to use for this function.
,
,
,
,
,
A bistable OC output can ONLY be deactivated by sending an SMS message consisting of the User code
between two # characters, the Control string and the characters “=OFF#”,as follows:
#User code#String=OFF# (example: #9876#HOUSELIGHT=OFF#)
,
,
,
,
,
The default User code is ‘0001’; if you wish to change it, please refer to the section “Remote programming->Changing
the User code”.
Monostable Outputs
Monostable OC outputs can be activated in 2 ways:
1.
By sending an SMS consisting of the
User code
between two
#
characters, the
Control string
(
Control String
can
not have initial blank spaces) and the characters “
=ON#
”,“
=ON#TonU#
” or “
=OFF#
”,as follows:
#Account code#String=ON#
#Account code#String=ON#TonU#
#Account code#String=OFF#
The “
=ON#tonU#
” option is parameter allows to set the
ON Time
from 1 to 86400 seconds, with 1 second steps. The
ON
Time
can be set by means of the Communicator's console software. “
Ton
” is the required value and “
U
” is the unit in hours
(
H
), minutes (
M
) and seconds (
S
), as shown in the following example:
SMS
Output operating mode
#9876#HOUSELIGHT=ON#
Bistable Activation
#9876#HOUSELIGHT=ON#3600S#
Active for 3600 seconds
#9876#HOUSELIGHT=ON#50M#
Active for 50 minutes
#9876#HOUSELIGHT=ON#3600#
Active as per software programming,
the set ON time does not apply