55
Item
Command
Example & Usage
Default
Remote
Firmware
Upgrade
FWUG
FWUG:PROG,1111,59.124.230.221,53033,/img/123.bin,042d
Upgrade Mobile Lite firmware by downloading firmware file from
server remotely.
Parameter 1: Server IP Address (Max 44 characters)
Parameter 2: Server Port Number
Parameter 3: File path(max 31 characters)
Parameter 4: crc16 check sum
Remove RF
Device
DEVRM
DEVRM:PROG,1111,1
Remove RF Device in Mobile Lite
Parameter 1: Zone number to be removed (1~5)
Add RF
Device
DEVAD
DEVAD: PROG,1111,1234567890
Add RF Device into Mobile Lite using device RF code
Parameter 1: Device RF Code (Max 10 digits)
--
To enable /
disable
silent mode
SILENT
SILENT:PROG,1111,1
Enable/disable mobile silent mode
Disable = 0, Enable = 1
0
To
enable/disab
le pressing
sensor
button to
end call
CUTV
CUTV:PROG,1111,1
Enable/disable pressing sensor button to end call.
Disable = 0, Enable = 1
0
To
enable/disab
le Fall
Detection
function
FALDE
FALDE:PROG,1111,1
Enable/disable Fall Detection function of Mobile Lite R8/R18.
Disable = 0, Enable = 1
To set Fall
sensor 3
sensitivity
FSST
FSST:PROG,1111,1
To set Fall sensor 3 sensitivity.
Sensitivity: 1-5
(5 is the highest sensitivity, while 1 is the lowest sensitivity)
Upload
current
Mobile Lite
settings
ULOAD
ULOAD:PROG,1111,us.vestasmarthome.com,8768,8662580405490
39
To upload current Mobile Lite settings to server
Parameter 1: Host (server url or IP adress)
Parameter 2: Port number
Parameter 3: Session ID (maximum length: 16 digits)
7.2. Contact ID Communications Protocol and Format
Mobile Lite can communicate with the CMS receiver using the Contact ID
protocol. The CMS can receive the event codes using SMS or IP reporting
methods.
The form of the CID message is:
IP Reporting Data Format
[ACCT
<space>
MT QXYZ GG CCC S
1
S
2
S
3
S
4
]
[ ]
All data inside bracket will be processed.
ACCT