Shelf Manager CLI
Fortinet Technologies Inc.
The shelf manager command line interface agent (CLIA)
Once you have logged into the shelf manager CLI you use the Command Line Interface Agent (CLIA) to enter shelf
manager commands. Usually you do this from the Linux command line by entering clia followed by the required CLIA
command verb and parameters. The CLIA executable connects to the main Shelf Manager software process, passes
the command information to it and retrieves the results.
For example, you can enter the following command to list the most commonly used CLIA commands:
clia help
You can also use the help command to get more information about specific CLIA commands. For example, use the
following command display help for the
shelf pwrreorder
command:
clia help shelf pwrreorder
Pigeon Point Shelf Manager Command Line Interpreter
Change the order of FRU Activation and Power Descriptors
instead of <addr> <fru_id> user may use:
board <N>
shm <N>
power_supply <N> (valid in 2.x systems only)
fan_tray <N>
PwrReorder <addr1> <fru_id1> before/after <addr2> <fru_id2>
Using CLIA interactive mode
You can also enter
clia
without parameters to enter interactive mode. In the interactive mode, the shelf manager CLI
issues a prompt to the terminal, accepts user input as the next command with parameters, executes that command and
shows the results on the terminal, until you enter the command
exit
or
quit
. For example:
# clia
Pigeon Point Shelf Manager Command Line Interpreter
CLI> version
Pigeon Point Shelf Manager ver. 2.5.1
Pigeon Point is a trademark of Pigeon Point Systems.
Copyright (c) 2002-2006 Pigeon Point Systems
Build date/time: Nov 3 2006 09:43:12
All rights reserved#
IPMB addresses, logical and physical slot numbers, and FRU ids
The shelf manager manages the chassis over the Intelligent Platform Management Bus (IPMB). All of the chassis slots
have IPMB addresses (as well as hardware addresses) on this bus. When you enter shelf manager CLI commands you
indicate chassis slot numbers according to their IPMB addresses. The IPMB and hardware addresses are in
hexadecimal format.
FortiGate-5144C 6.2.3 Chassis Guide