:DIGitizer[N]:CHANnel[M]:ENABle?
Query
:DIGitizer[N]:CHANnel[M]:ENABle?
Description
This query returns the active status of channels.
Under certain error conditions, the module can disable a channel that will require
a module reset to enable again. Returns std_int32, [1=Enabled,0=Disabled].
Example
-> dig3:chan1:enab?
<- 1
:DIGitizer[N]:CHANnel[M]:TINTerleave[?]
Command
:DIGitizer[N]:CHANnel[M]:TINTerleave
Description
This command configures channel interleave for modules that support this feature.
The value is entered as std_int32. 1=interleave, 0=no interleave. The system error
buffer returns the errors.
Example
-> dig3:chan1:tint 0
Query
:DIGitizer[N]:CHANnel[M]:TINTerleave?
Description
This query returns channel interleave status as std_int32. 1=interleave, 0=no
interleave.
Example
-> dig3:chan1:tint?
<- +0
:DIGitizer[N]:CHANnel[M]:BYPass[?]
Command
:DIGitizer[N]:CHANnel[M]:BYPass
Description
This command enables filter bypass mode for BW limiter filter, std_int32.
1=bypass, 0=no bypass
Example
-> dig3:chan1:byp 0
Query
:DIGitizer[N]:CHANnel[M]:BYPass?
Description
This query returns the status of bandwidth limiter filter bypass, std_int32.
1=bypass, 0=no bypass