NAUT324C-256K
- Technical reference - Rev. B
Page 56
18.2. Parameters details
Param. Address 1: Baud Rate:
Param. = 0: 115,200 Baud
Param. = 1: 115,200 Baud
Param. = 2: 115,200 Baud
Param. = 3: 115,200 Baud
Param. = 4: 115,200 Baud
Param. = 5: 57,600 Baud
Param. = 6: 38,400 Baud
Param. = 7: 19,200 Baud
Param. = 8: 9,600 Baud
(default)
Param. = 9: 4,800 Baud
Param. = 10: 2,400 Baud
Param. = 11: 1,200 Baud
Param. = 12: 600 Baud
[Command example] <ESC>V<1d><7d> sets the baud rate to 19.200 permanently.
Param. Address 2: RS232 Params: (Flag Byte)
No Parity xx00 xxxx
Unused xx01xxxx
Even Parity xx10 xxxx
Odd Parity xx11 xxxx
1 Stop Bit xxxx 0xxx
2 Stop Bits xxxx 1xxx
7 Data Bits xxxx xx0x
8 Data Bits xxxx xx1x
Default set: 0000 0010 binary = 2 decimal
Example to set permanently 8 data bits, 1, stop, no parity
Parameter = 0000 0010 binary = 2 decimal
Command: <ESC>V<2d><2d>
Note: Bits marked with an "x" should be set to "0".
Parameter Address 3: Blackening
This parameter has a value range from 0 to 50.
Default value is 50
High values result in strong blackening.
Blackening. Value 35 is a typical standard value for medium blackening density.
[Parameter example] Set blackening to value of 40 permanently: <ESC>V<3d><40d>
Important note:
do not change the original setting of parameter 3 if not extremely required,
value 50 is maximum allowed, do not use greater values otherwise the printer could get
damage.