Circuit ID Configuration
The x4120 supports a Device Description at the device level and a Circuit ID at the port level.
The Circuit ID provides the option to configure an ASCII text string up to 63 bytes and override the default
information, which is vlan-module-port in binary format.
The Circuit ID can be configured in the x4120 using either the CLI or Web method.
Circuit ID Config – CLI Method
1. Access the NID through either a USB connection or a Telnet session.
2. At the device’s command prompt type:
set circuit-ID=
<xx> where:
xx
= the Circuit ID to be used for this device or port.
3. Press
Enter
.
4. Verify the Circuit ID setting. Type
show circuit-ID
and press
Enter
. Note that the dash (“-“) is
required, and the letters “ID” must be upper-case. The Circuit ID information displays. For example:
C1|S16|L1D>
set circuit XX/YYYY/000000/111/CC/SEG
C1|S16|L1D>
show circuit-ID
Circuit-ID: XX/YYYY/000000/111/CC/SEG
C1|S16|L1D>
5. At the each of the device port’s command prompts, enter the Circuit ID as in step 2 and 3.
6. At the each of the device port’s command prompts, verify the Circuit ID setting as in step 4.
For example:
C1|S16|L1D>
go l1p=1
C1|S16|L1P1>
set circuit-ID=xx/yyyy/000000/111/cc/seg
C1|S16|L1P1>
show circuit-ID
Circuit-ID: xx/yyyy/000000/111/cc/seg
C1|S16|L1P1>
C1|S16|L1P1>
go l1p=2
C1|S16|L1P2>
set circuit XX/YYYY/000000/111/CC/SEG
C1|S16|L1P2>
show circuit-ID
Circuit-ID: XX/YYYY/000000/111/CC/SEG