MOTOROLA
M68020 USER’S MANUAL
8- 39
8.2.17 Exception-Related Instructions
The exception-related instructions table indicates the number of clock periods needed for
the processor to perform the specified exception-related action. Footnotes specify when it
is necessary to add the entry from another table to calculate the total effective execution
time for the given instruction. The total number of clock cycles is outside the parentheses;
the number of read, prefetch, and write cycles is given inside the parentheses as (r/p/w).
These cycles are included in the total clock cycle number.
Instruction
Best Case
Cache Case
Worst Case
BKPT
9(1/0/0)
10(1/0/0)
10(1/0/0)
Interrupt (I-Stack)
26(2/0/4)
26(2/0/4)
33(2/2/4)
Interrupt (M-Stack)
41(2/0/8)
41(2/0/8)
48(2/2/8)
RESET Instruction
518(0/0/0)
518(0/0/0)
519(0/1/0)
STOP
8(0/0/0)
8(0/0/0)
8(0/0/0)
Trace
25(1/0/5)
25(1/0/5)
32(1/2/5)
TRAP #n
20(1/0/4)
20(1/0/4)
27(1/2/4)
Illegal Instruction
20(1/0/4)
20(1/0/4)
27(1/2/4)
A-Line Trap
20(1/0/4)
20(1/0/4)
27(1/2/4)
F-Line Trap
20(1/0/4)
20(1/0/4)
27(1/2/4)
Privilege Violation
20(1/0/4)
20(1/0/4)
27(1/2/4)
TRAPcc (Trap)
23(1/0/5)
25(1/0/5)
32(1/2/5)
TRAPcc (No Trap)
1(0/0/0)
4(0/0/0)
5(0/1/0)
TRAPcc.W (Trap)
23(1/0/5)
25(1/0/5)
33(1/3/5)
TRAPcc.W (No Trap)
3(0/0/0)
6(0/0/0)
7(0/1/0)
TRAPcc.L (Trap)
23(1/0/5)
25(1/0/5)
33(1/3/5)
TRAPcc.L (No Trap)
5(0/0/0)
8(0/0/0)
10(0/2/0)
TRAPV (Trap)
23(1/0/5)
25(1/0/5)
32(1/2/5)
TRAPV (No Trap)
1(0/0/0)
4(0/0/0)
5(0/1/0)
Summary of Contents for MC68020
Page 16: ...9 29 95 SECTION 1 OVERVIEW UM Rev 1 0 xx M68020 USER S MANUAL MOTOROLA ...
Page 268: ...MOTOROLA M68020 USER S MANUAL 9 13 Figure 9 9 Access Time Computation Diagram ...
Page 286: ...MOTOROLA M68020 USER S MANUAL 10 11 Figure 10 3 Read Cycle Timing Diagram ...
Page 287: ...10 12 M68020 USER S MANUAL MOTOROLA Figure 10 4 Write Cycle Timing Diagram ...
Page 288: ...MOTOROLA M68020 USER S MANUAL 10 13 Figure 10 5 Bus Arbitration Timing Diagram ...