REMOTE OCEAN SYSTEMS
SEASTAR OPERATION AND MAINTENANCE MANUAL
10-01313 REV D
16
Table 4. Serial Commands and Inquiries
Command
Packet
Note
Set Intensity
8x 01 10 01 yy ff x = address
yy = Intensity (0x00
–
0x64 hex, 0 - 100 decimal)
Returns Command Completed if successful
Set Power Up Intensity
8x 01 10 02 yy ff x = address
yy = Intensity (0x00
–
0x64 hex, 0 - 100 decimal)
Returns Command Completed if successful
Get Factory Info
8x 09 06 50 ff
x = address
Returns comma separated factory information. The first two
bytes are hex, all other bytes are text.
z0 50 [unit pn],[unit rev],[unit sn],[cca pn],[cca rev],[cca
sn],[firmware pn],[firmware rev]
z = a 8 (byte)
Get Temperature
8x 09 10 03 ff
x = address
Returns z0 10 10 03 0y 0y 0y ff
z = a 8 (byte)
yyy = Hexadecimal temperature in Kelvin
Get Intensity
8x 09 10 04 ff
x = address
Returns z0 10 10 04 yy ff
z = a 8 (byte)
yy = Light intensity percent (0x00
–
0x64 hex, 0 - 100 decimal)
Get Power Up Intensity
8x 09 10 05 ff
x = address
Returns z0 10 10 05 yy ff
z = a 8 (byte)
yy = Light intensity percent (0x00
–
0x64 hex, 0 - 100 decimal)
Get Error
Status
8x 09 10 06 ff
x = address
Returns z0 10 10 06 0y ff
z = a 8 (byte)
y = 4 bits:
bit 0 = MOSFET over-current true/false
bit 1 = Driver Output over-voltage true/false
bit 2 = LED over-current true/false
bit 3 = 0