Appendix 1 list of Parameters
State 16.11.15
Misprints and technical changes reserved
Page 17
13: Command/Status Words
ID
Name
Value-Range
Default-Value
Unit
Access
560 General Stat
0000h ... FFFFh
---
[bits]
R
Displays the most important operation conditions for the drive.
Bit Name
Notes
0 Ready
1 Running
2 Speed > 0
3 Speed > X
Also see Par.510
4 Powerstage active
5 I-Limit reached
Also see Par.512
6 I > X
Also see Par.511
7 Generator Mode
8 Collective Error
9 Value out of range
10 Set-Value reached
11 n-set/n-act in tolerance range
Tolerance = 1% of the max. rotational speed (Par.101)
12 Fieldbus controlling
13 Current > Motor Rated Current
14 Field Weakening active
15 Asynch Control active
Asynchronous motor active
13: Command/Status Words
ID
Name
Value-Range
Default-Value
Unit
Access
561 Motor Stat
0000h ... 000Fh
---
[bits]
R
Display of auto-tuning status (ASM)
Bit Name
Notes
0 Auto tuning started
1 Auto tuning and run
2 Auto tuning finshed
13: Command/Status Words
ID
Name
Value-Range
Default-Value
Unit
Access
562 Drive Stat
0000h ... FFFEh
---
[bits]
R
565 Spd Prst Sel
[00] --- ... [07] Spd Preset 7
[00] ---
[bits]
RW
566 Ramp Sel
[00] Ramp 0 ... [07] Ramp 7
[00] Rampe 0
[bits]
RW
13: Command/Status Words
ID
Name
Value-Range
Default-Value
Unit
Access
567 Selected Reference Speed Source
[00] Preset Speed ...[08] Positioning
---
---
R
Display of active setpoint reference sources
Nr. Name
Notes
0
Preset Speed
1
2
3
Analog input Terminal 8
4
Master/Slave
Incremental
5
Motorpoti
6
Fieldbus
7
8
Positioning