44
DeviceNet Module Installation and Operation Manual
Table 62. AC/DC Drive Object Common Services.
AC/DC Drive Object Specific Services
The AC/DC Drive Object provides no object specific services.
10
Current Limit
INT
Get/Set
Motor phase current limit
Units: 100 mA
-
11
Torque Actual
INT
Get
ASD torque
Units: N•m
-
15
Power Actual
INT
Get
Torque reference
Units: N•m
-
18
Acceleration Time
UINT
Get/Set
Acceleration time:
Time from 0 to High Speed Limit
Units: ms
-
19
Deceleration Time
UINT
Get/Set
Acceleration time:
Time from 0 to High Speed Limit
Units: ms
-
20
Low Speed Limit
UINT
Get/Set
Minimum speed limit
Units: rpm
-
21
High Speed Limit
UINT
Get/Set
Maximum speed limit
Units: rpm
-
26
Power Scale
SINT
Get
Power scaling factor
-
29
Ref From Net
BOOL
Get
Status of torque/speed reference
0 = Local torque/speed reference
1 = DeviceNet torque/speed reference
-
46
Drive Power-On
Hours
DINT
Get
Total number of hours drive has had power
applied
Units: hours
-
Service
Code
Service Name
Supported
Class
Supported
Instance
Description of Service
0x0E
Get_attribute_single
Yes
Yes
Returns the contents of the specified attribute
0x10
Set_attribute_single
N/A
Yes
Modifies the value of the specified attribute
Attribute
ID
Name
Data
Type
Access
Rules
Description
Default
Value