3
deutsch
3
E
english
Contents
Safety Considerations ................................................................................................................. 4
Introduction BIS C Identification System ................................................................................. 5-7
Application BIS-C60_1 Processor, Basic knowledge for application ....................................... 8/9
BUS interface: InterBus ........................................................................................................ 10/11
Compatibility with BIS C-6_1 processor ................................................................................... 12
Function Description:
Communication with the processor .................................................. 13
In- and output buffer on INTERBUS ............................................ 14/15
Output buffer, configuration and explanation .............................. 16-20
Input buffer, configuration and explanation ................................. 21-24
Configuring the BIS C-60_1 processor ........................................ 25-27
Processing code tags .................................................................. 28-34
Reading and writing ............................................................... 28
Data carrier Present / Auto-Read .......................................... 29
Reading and writing in dynamic mode .................................. 30
Reading and writing with simultaneous data transmission .... 30
Copying from Head 1 to Head 2 ............................................ 31
CRC initialization ................................................................... 32
Mixed Data Access ........................................................... 33/34
Reading and writing with program ......................................... 35
Examples for protocol sequence ................................................. 36-55
Read/Write Times ................................................................................................................. 56/57
LED Display .......................................................................................................................... 58/59
BIS C-6001
BIS C-6021
Mounting Head / Processor .............................................................................. 60 .................. 73
Opening the processor / Interface information .................................................. 61 .................. 74
Installing the connection cables / Mounting the PG connection .................. 62/63
Interface information / Wiring diagrams ....................................................... 64-68 ............. 75-79
Changing the EEPROM ..................................................................................... 69 .................. 80
Technical Data .............................................................................................. 70/71 ............. 81/82
Ordering information ......................................................................................... 72 .................. 83
Appendix, ASCII Table .............................................................................................................. 84
C60_1-023_819395_0508_en.p65
4
4
E
Safety Considerations
Series BIS C-60_1 processors along with the other BIS C system components comprise an
identification system and may only be used for this purpose in an industrial environment in
conformity with Class A of the EMC Law.
Installation and operation should be carried out by technically trained personnel only.
Unauthorized access and improper use will lead to loss of warranty and liability claims.
When installing the processor, consult the section on wiring diagrams carefully. Special
caution must be used when wiring the processor to external controllers, particularly with
respect to selection and polarity of the signals and power supply.
Only approved power supplies may be used with the processor. See the section on Technical
Data for details.
The relevant safety procedures must be followed when using the Identification System. In
particular, steps must be taken to ensure that no danger to persons or equipment can arise
should a fault occur in the Identification System.
This includes maintaining the published ambient operating conditions and regular checking of
the functionality of the Identification System with all its associated components.
As soon as there is evidence that the Identification System is not functioning properly, it
should be taken out of service and protected against unauthorized use.
This description is valid for series BIS C-6001-023...03-KL2 processors and both the ST8 and
ST9 versions of series BIS C-6021-023-050-03-ST_.
Installation and
Operation
Use and Checking
I
NTER
B
US
is a registered trademark of the Phoenix Corporation.
Fault Conditions
Scope
Approved operation