38
SET PROCESS PARAMETERS
Certain process parameters can be set by the user to customize the programming. Select SET PROCESS
PARAMETERS to change. Changes are retained on power down. If you mess up simply select DEFAULT and the unit
will reset to factory settings. Be aware that this will also erase any logged events.
Only advanced users should change these parameters. Consult with
PARAMETER
DESCRIPTION
RANGE
DEFAULT
AutoWiFi
RETRY WIFI IF CONNECTION LOST
NO/YES
YES
WiFiEnbl
ENABLE WIFI CONNECTIONS
NO/YES
YES
PunchINflMins
INFLATION TIME DURING PUNCH (MINS)
0 TO 20
2 MINUTES
PunchPsigx10
INFLATION PRESSURE DURING PUNCH
0 TO 20 (PSIX10)
3 (0.3PSI)
PunchDefMins
DEFLATION TIME DURING PUNCH (MINS)
0 TO 30
7 MINUTES
PunchTOmins
PUNCH TIMEOUT (MINS)
0 TO 30
10 MINUTES
PressINflMins
INFLATION TIME DURING PRESS (MINS)
0 TO 30
15 MINUTES
PressPsigx10
INFLATION PRESSURE DURING PRESS
0 TO 20 (PSIX10)
10 (1.0PSI)
PressDefMins
DEFLATION TIME DURING PRESS (MINS)
0 TO 60
10 MINUTES
PressTOmins
PRESS TIMEOUT (MINS)
0 TO 30
15 MINUTES
HR
LOCAL TIME- HOUR
0 TO 23
SET BY INTERNET
MIN
LOCAL TIME - MIN
0 TO 59
SET BY INTERNET
MONTH
LOCAL TIME- MON
1 TO 12
SET BY INTERNET
DAY
LOCAL TIME -DAY
1 TO 31
SET BY INTERNET
YY
LOCAL TIME - YEAR
0 TO 99
SET BY INTERNET
TCON
TEMPERATURE CONTROL ON (JR+ ONLY)
NO/YES
UNUSED
TSPx5
TEMP SETPOINT DEGC X 5 (JR+ ONLY)
25 TO 200
150 (30 C)
DEGF
TEMPERATURE UNITS (JR+ ONLY)
NO/YES
YES
TempEnbl
TEMPERATURE SENSOR ENABLED (JR+ ONLY)
NO/YES
NO
TCRTL_MODE
0=OFF 1=COOLING 2=HEATING (JR+ ONLY)
0,1,2
0 (OFF)