72 Commands
SET_TRIGGER_CMD
Command packet
1. The length is variable, depending on the selected command.
Description
Set the trigger command to be executed when the trigger line is asserted
Parameters
Opcode, Length, Param1, Param2, Param3
Parameter
Description
Opcode (unsigned eight-bit)--opcode of command to be executed
Length --the length of the data portion
Param1, Param2, Param3 (unsigned eight-bits)--first, second, and third parameter of the
selected command (number of parameters ranges from 0 to 3 depending of the selected
command)
Note that the default opcode is for reset (0x00
OPCODE
Length
Parameters
0x3F
0x02 to
0x0A
1
U8 Opcode, U8 Length, U8 Param1, U8 Param2, U8 Param3
Opcode (unsigned eight-bit)--Opcode of the command selected to be exe-
cuted as part of the trigger command (0x20 to 0x27)
Param1-Param8 (unsigned eight bit)--Data payload bytes specific to the
opcode specified.
Summary of Contents for SKB Series
Page 1: ...SKB SERIES FIBEROPTIC SWITCH MODULE User Manual ...
Page 2: ...ii 10109002 Rev 001 August 2001 2001 JDS Uniphase All rights reserved ...
Page 4: ...iv ...
Page 11: ...7 Contents ...
Page 13: ...9 List of Figures ...
Page 15: ...11 List of Tables ...
Page 19: ...4 Safety Information Instructions and Symbols ...
Page 25: ...10 Introduction ...
Page 53: ...38 Operation and Control Instructions ...
Page 91: ...76 Commands ...
Page 111: ...96 Application Notes ...
Page 113: ...98 Service ...