Commands 43
ALARM?
Command packet
Response packet
EPV (EEPROM VERIFY FAIL, bit 15)--This bit indicates that the verify operation of an EEPROM
write failed. It is cleared when the AR is read.
OT (OVER TEMPERATURE, bit 14)--This bit indicates that ambient temperature of the module has
exceeded the high temperature threshold for a period of at least 10 seconds. It is cleared when the
temperature falls below the high temperature threshold.
UT (UNDER TEMPERATURE, bit 13)--This bit indicates that ambient temperature of the module has
dropped below the low temperature threshold for a period of at least 10 seconds. It is cleared when
the temperature falls below the high temperature threshold.
CFO (CONFIGURATION OVERFLOW, bit 12)--This bit indicates that user configuration commands
have been executed more than 50,000 times. This bit is not cleared when the configuration com-
mand counter exceeds 50,000. This bit can only be cleared at the JDS Uniphase factory.
Description
Query the alarm register value
Parameters
NA
Parameter
Description
NA
OPCODE
Length
Parameters
0x03
0x00
OPCODE
Length
Parameters
0x83
0x02
U16 Alarm_reg
Alarm_reg (unsigned 16-bit)--Current binary value of the Alarm Register
(AR), as indicated in the following table
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
EPV
OT
UT
CFO
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Initial value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Summary of Contents for SKB Series
Page 1: ...SKB SERIES FIBEROPTIC SWITCH MODULE User Manual ...
Page 2: ...ii 10109002 Rev 001 August 2001 2001 JDS Uniphase All rights reserved ...
Page 4: ...iv ...
Page 11: ...7 Contents ...
Page 13: ...9 List of Figures ...
Page 15: ...11 List of Tables ...
Page 19: ...4 Safety Information Instructions and Symbols ...
Page 25: ...10 Introduction ...
Page 53: ...38 Operation and Control Instructions ...
Page 91: ...76 Commands ...
Page 111: ...96 Application Notes ...
Page 113: ...98 Service ...