Error 15-20
Invalid input position selector value (MPRO_CAM_CamInPosFS)
An invalid value is stored in parameter
P 1427 MPRO_CAM_CamInPosFS
. The number displayed is the invalid
value found in the parameter.
Error 15-20:
Wrong CamSizeConf value! Max. 64 values allowed.
Too many cam positions have been specified in parameter
P 1421 MPRO_CAM_CamSizeConf
. A maximum
of 64 is allowed. The number shown in the error message indicates the track for which the number of configured
cam positions is configured incorrectly (0 = track 1, 1 = track 2, 2 = track 3, 3 = track 4).
Error 15-20:
Wrong CamSizeConf value! Please configure an even number of cam edges.
An odd number of cam positions has been specified in the parameter MPRO_CAM_CamSizeConf. The number
of cam positions must always be even, i.e. each cam must be defined completely with a start and end position.
If necessary, the configuration of the cam positions must also be checked in parameter
P 1430 MPRO_CAM_
CamTrack1Conf
-
P 1433 MPRO_CAM_CamTrack4Conf
. The number shown in the error message indicates
the track for which the number of configured cam positions is configured incorrectly (0 = track 1, 1 = track 2, 2 =
track 3, 3 = track 4).
Error 15-20:
Wrong CamTrackConf configuration! All configured cam edges have to be in ascending order.
Cam positions are not specified in ascending order in one of the parameters
P 1430 MPRO_CAM_
CamTrack1Conf
-
P 1433 MPRO_CAM_CamTrack4Conf
. The track and cam position that caused the error
are coded in the number given in the error message. The track is coded in the hundreds position of the number (0
= track 1, 1 = track 2, 2 = track 3, 3 = track 4). The cam position in the track is coded in the tens and ones
position of the number.
Table 8.53: Error message 15-20
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
300
8 Motion profile
8.15 Data handling
ID
Index Name
Unit Description
2920
0
MPRO_DATA_Ctrl
Extended data control word
2921
0
MPRO_DATA_Stat
Extended data status word
2922
0
MPRO_DATA_Act
Actual signal value
2923
0
MPRO_DATA_Upper
Reference upper limit value
2924
0
MPRO_DATA_Lower
Reference lower limit value
2925
0
MPRO_DATA_Ref
Reference value
2926
0
MPRO_DATA_Signal
Signal selection
2927
0
MPRO_DATA_ActIdx
Actual index of value
2928
MPRO_DATA_Info
Extended data information
2928
0
MPRO_DATA_MaxIdx
Maximum stored values
2928
1
MPRO_DATA_Crc
CRC of stored values
2929
MPRO_DATA_Value
Feed-forward calculation mode
2929
0
MPRO_DATA_
UpperLimit
Upper limit offset
2929
1
MPRO_DATA_
LowerLimit
Lower limit offset
2930
0
MPRO_DATA_
DataName
Name of data set
Table 8.54: “Data handling” parameters