4.10
Resource Programming
Floating Number Assignment
813
4-134
System Programming
*: Available for KX-TD1232 only.
Description
Assigns the floating numbers for External Pagers, modem,* and the
Digital Test Access (DTA). These numbers can be used the same
way extension numbers are used for station access.
Selection
• Floating station: KX-TD816 – Pager1 / DTA
KX-TD1232 – Pager1 / Pager2 / Pager3 /
Pager4 / MODEM / DTA
• Floating number: 2 through 4 digits
Default
KX-TD816 – Pager 1=296; DTA=299
KX-TD1232 – Pager 1=296; Pager 2=297; Pager 3=396;
Pager 4=397; MODEM=399; DTA=299
Programming
1.
Enter 813.
Display: FLT EXT NO.
2.
Press NEXT to program Pager 1.
Display example: Pager1:EXT296
To program another floating station, keep pressing NEXT or PREV
until the desired floating station is displayed.
3.
Enter a floating number.
To change the current entry, press CLEAR and the new floating
number.
4.
Press STORE.
5.
To program another floating station, keep pressing NEXT or
PREV until the desired floating station is displayed.
6.
Repeat steps 3 through 5.
7.
Press END.
Conditions
• A floating number is composed of two through four numerical digits, 0
through 9.
• The leading one or two digits of the floating numbers are subject to
program [100] “Flexible Numbering, (01) through (16) 1st through 16th
hundred extension blocks.”
• Floating numbers and extension numbers should be unique. Double
entry and incompatible entry for these numbers are invalid. Valid entry
example: 10 and 11, 10 and 110; Invalid entry example: 10 and 106,
210 and 21.
• You cannot leave the entry empty.
Feature References
Section 3, Features,
Floating Station