Robotiq 3-Finger Adaptive Robot Gripper
Instruction Manual
Robotiq inc. © 2008 - 2014
72
Response is:
09 10 03 E8 00 03 01 30
where
BITS
DESCRIPTION
09
SlaveID
10
Function Code 16 (Preset Multiple Registers)
03E8
Address of the first register
0003
Number of written registers
0130
Cyclic Redundancy Check (CRC)
Step 8: Read gripper status until the opening is completed
Request is:
09 03 07 D0 00 08 45 C9
where
BITS
DESCRIPTION
09
SlaveID
03
Function Code 03 (Read Holding Registers)
07D0
Address of the first requested register
0008
Number of registers requested (8)
45C9
Cyclic Redundancy Check (CRC)
Example of response if the opening
:
is not completed
09 03 10 39 C0 00 00 B8 0B 00 BD 0E 00 BA 0B 00 89 00 00
10 85
where
BITS
DESCRIPTION
09
SlaveID
03
Function Code 03 (Read Holding Registers)