PLC-ET30L Expand Serial Command Functional Specifications
39/62
9.4.4 CR_TINT Command
Command
“CR_TINT” [CR]
Details
Get user controlled value of Tint
Response
Acceptable
“000_%1” [CR]
%1
“000 – 063”
Unacceptable
“Error Code” [CR] --- When command is not available in the given
condition (such as being selected input).
“?” [CR] --- When unknown command is received
9.4.5 CR_SHARP Command
Command
“CR_SHARP” [CR]
Details
Get user controlled value of Sharpness
Response
Acceptable
“000_%1” [CR]
%1
“000 – 015”
Unacceptable
“?” [CR]
9.4.6 CR_GAMMA Command
Command “CR_GAMMA” [CR]
Details
Get user controlled value of Gamma
Response
Acceptable
“000_%1” [CR]
%1
“000 – 015”
Unacceptable
“?” [CR]
9.4.7 CR_WBAL-R Command
Command
“CR_WBAL-R” [CR]
Details
Get user controlled Red value of White Balance
Response
Acceptable
“000_%1” [CR]
%1
“000 – 063”
Unacceptable
“?” [CR]
9.4.8 CR_WBAL-G Command
Command
“CR_WBAL-G” [CR]
Details
Get user controlled Green value of White Balance
Response
Acceptable
“000_%1” [CR]
%1
“000 – 063”
Unacceptable
“?” [CR]
9.4.9 CR_WBAL-B Command
Command
“CR_WBAL-B” [CR]
Details
Get user controlled Blue value of White Balance
Response
Acceptable
“000_%1” [CR]
%1
“000 – 063”
Unacceptable
“?” [CR]