PLC-ET30L Expand Serial Command Functional Specifications
56/62
9.11.9 CR_RTYPE Command
Command
“CR_RTYPE” [CR]
Details
Get status of supported Remote Control (IR/RF).
Response
Acceptable
“000_%1” [CR]
%1
“IR” -------- IR
“RF” ------- RF (cannot be returned as this model supports only
IR remote control)
Unacceptable “Error Code” [CR]
9.11.10 CR_LANG Command
Command
“CR_LANG” [CR]
Details
Get selected language
Response
Acceptable
“000_%1” [CR]
%1
“ENG” -------------------------- English is selected
“DEU” -------------------------- German is selected
“FRA” -------------------------- French is selected
“ITA” --------------------------- Italian is selected
“ESP” -------------------------- Spanish is selected
“POR” -------------------------- Portuguese is selected
“NED” -------------------------- Dutch is selected
“SVE” -------------------------- Swedish is selected
“JPN” -------------------------- Japanese is selected
“CHI” -------------------------- Chinese is selected
“KOR” -------------------------- Korean is selected
“RUS” -------------------------- Russian is selected
Unacceptable
“?” [CR]
9.11.11 CR_ON-STA Command
Command
“CR_ON-STA” [CR]
Details
Get setting status of Power ON Start
Response
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- Power ON Start is ON
“OFF” ------------------------ Power ON Start is OFF
Unacceptable
“?” [CR]
9.11.12 CR_P-MANE Command
Command
“CR_P-MANE” [CR]
Details
Get setting status of Power management
Response
Acceptable
“000_%1” [CR]
%1
“OFF” ------------------------ Power Management is disabled
“READY” -------------------- Power Management is set to Ready
“SHUTDOWN” ----------- Power Management is set to Shut
Down mode
Unacceptable “?” [CR]