PLC-ET30L Expand Serial Command Functional Specifications
52/62
9.8.6 CR_HPOS Command
Command
“CR_HPOS” [CR]
Details
Get setting status of H Position
Response
Acceptable
“000_%1” [CR]
%1
“-15”
−
”015”
Unacceptable “?” [CR] -------------------- When unknown command is received
9.9 Lamp Status Read Command
9.9.1 CR_LAMPREPL Command
Command
“CR_LAMPREPL” [CR]
Details
Get information of Lamp Replacement time
Response
Acceptable
“000_%1” [CR]
%1
“1Y” ----------------- indicates over lamp replacement time
“1N” ----------------- indicates under lamp replacement time
“1” means the number of lamps
(1 lamp is used
→
“1”)
“Y”/”N” means if it is time to replace lamp or not.
Example:
“1Y” ----- 1 lamp is used and it is over lamp replacement time
Unacceptable “?” [CR]
9.9.2 CR_LAMPH Command
Command
“CR_LAMPH” [CR]
Details
Get Lamp running time (in hours)
* return actual lamp running time
Response
Acceptable
“000_%1” [CR]
%1
“00000 - 99999”
Unacceptable “Error Code” [CR]
9.9.3 CR_LAMPCORRESPH Command
Command
“CR_LAMPCORRESPH” [CR]
Details
Get Lamp running time (in hours)
*return lamp running time multiplied by a coefficient (not actual running time)
Response
Acceptable
“000_%1” [CR]
%1
“00000 – 99999”
Unacceptable “Error Code” [CR]