9.7.8 CR_SYSLIST Command
Command
“CR_SYSLIST” [CR]
Details
Get possible systems for System list
Response
Acceptable
“000_%1_%2_---_%x” [CR]
%1
When Input is PC Analog:
“XGA” ------------------- XGA is in the list
“1080I” ----------------- 1080i is in the list
*Auto, Mode1-10 shall not be returned.
*When no signal is coming, error code “101” is returned.
When Input is PC Digital/AV HDCP:
“D-XGA” --------------- D-XGA is in the list
“D-720P” -------------- D-720p is in the list
*When no signal is coming, error code “101” is returned.
When Input is Y,Pb/Cb,Pr/Cr:
All possible systems in Menu, including Auto, are returned.
“AUTO” ----------------- Auto is in the list
“1080I” ----------------- 1080i is in the list
“1035I” ----------------- 1035i is in the list
:
:
“575I” ------------------- 575i is in the list
“480I” ------------------- 480i is in the list
*When no signal is coming, error code “101” is not returned.
When Input is Video/S-Video:
All possible systems in Menu, including Auto, are returned.
“AUTO” ----------------- Auto is in the list
“PAL” -------------------- PAL is in the list
“SECAM” --------------- SECAM is in the list
:
:
“PAL-N” ----------------- PAL-N is in the list
*When no signal is coming, error code “101” is not returned.
Unacceptable
“Error Code” [CR]
9.7.9 CR_MODELIST Command
Command
“CR_MODELIST” [CR]
Details
Get possible modes for Mode list
Response
Acceptable
“000_%1_%2_---_%x” [CR]
%1
Error Code “101” is returned except for PC-Analog and for no
signal with PC-Analog
Possible modes in Mode1-10 are returned when PC-Analog
signal is coming.
“MODE1”
“MODE2”
“MODE3”
:
:
“MODE8”
“MODE9”
“MODE10”
Unacceptable
“Error Code” [CR]