PLC-ET30L Expand Serial Command Functional Specifications
51/62
9.8 Screen Status Read Command
9.8.1 CR_SCREEN Command
Command
“CR_SCREEN” [CR]
Details
Get selected screen image size
Response
Acceptable
“000_%1” [CR]
%1
“NORMAL” ---------------------- Normal mode
“WIDE” --------------------------- Wide mode
“FULL” --------------------------- Full mode
“TRUE” --------------------------- True mode
“CUSTOM” ----------------------- Custom mode
Unacceptable
“Error Code” [CR] --- When command is not available in the
given condition (such as being selected input).
“?” [CR] --- When unknown command is received
9.8.2 CR_ KYSTNMODE Command
Command
“CR_KYSTNMODE” [CR]
Details
Get setting status of Keystone Store Mode
Response
Acceptable
“000_%1” [CR]
%1
“STR” ---------------------- Store mode is “Store”
“RST” ---------------------- Store mode is “Reset”
Unacceptable “?” [CR] -------------------- When unknown command is received
9.8.3 CR_VSCALE Command
Command
“CR_VSCALE” [CR]
Details
Get setting status of V scale
Response
Acceptable
“000_%1” [CR]
%1
“-32”
−
”032”
Unacceptable “?” [CR] -------------------- When unknown command is received
9.8.4 CR_VPOS Command
Command
“CR_VPOS” [CR]
Details
Get setting status of V Position
Response
Acceptable
“000_%1” [CR]
%1
“-15”
−
”015”
Unacceptable “?” [CR] -------------------- When unknown command is received
9.8.5 CR_HSCALE Command
Command
“CR_HSCALE” [CR]
Details
Get setting status of H scale
Response
Acceptable
“000_%1” [CR]
%1
“-32”
−
”032”