Table 29: Encoder control standard SFNC command
Command
Description
Access
EncoderReset
Resets the EncoderValue of the selected Encoder. The
Encoder starts counting events immediately after the reset.
EncoderReset can be used to reset the Encoder independ‐
ently from the EncoderResetSource.
W
16.2.9
Event control
Table 30: Event control standard SFNC selector
Selector
Type
Description
EventSelector
enum
Selects which Event to signal to the host application.
Value:
LogMessage
Table 31: Event control standard SFNC parameter
Parameter
Type
Description
Access
EventNotification[EventSelector]
enum
Activate or deactivate the notification to the host application
of the occurrence of the selected Event.
Values:
Off: The selected Event notification is disabled.
On: The selected Event notification is enabled.
RW
16.2.10
User Set control
Table 32: User Set control standard SFNC selector
Selector
Type
Description
UserSetSelector
enum
Selects the feature User Set to load, save or configure.
Default User Set is read-only and cannot be modified.
Values:
Default
UserSet1
UserSet2
UserSet3
UserSet4
UserSet5
Table 33: User Set control standard SFNC parameters
Parameter
Type
Description
Access
UserSetDefault[UserSetSelector]
enum
Selects the feature User Set to load and make active by
default when the device is reset.
Values:
Default
UserSet1
UserSet2
UserSet3
UserSet4
UserSet5
RW
Table 34: User Set control custom parameters
Parameter
Type
Description
Access
UserSetDescription[UserSetSelector]
string
Description of the content of a User Set.
RW
UserSetFirmwareVersion[UserSetSelec‐
tor]
string
The firmware version for which the configuration was created.
It is only possible to load user sets that are created for the
currently running firmware version.
R
16
ANNEX
108
O P E R A T I N G I N S T R U C T I O N S | Ruler3000
8026049//2021-04 | SICK