Programming via Rockwell controller
9.6 Programming the Ident profile
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
183
Parameter
Data type
Default val-
ue
Description
EXT_UHF
STRUCT
--
Structure for additional parameters (RF680R/RF685R
only)
LEN_ID
SINT
0
Length of the valid data in the "EPCID_UID" field.
MEM_BANK
SINT
3
Memory bank on the transponder
•
0x00 = RESERVED
•
0x01 = EPC
•
0x02 = TID
•
0x03 = USER
PSWD
DINT
0
Password for transponder access
0x00 ≙ no password
EDIT_BLACKLIST_MODE SINT
0
Mode
•
0x00 = add EPC-ID
•
0x01 = add all "Observed" transponders
•
0x02 = delete EPC-ID
•
0x03 = delete all
INVENTORY_DURATION
DINT
0
Duration
Period of time or number of inventories or number of
"Observed" events
Example:
•
0x00 ≙ no inventory
•
0x01 ≙ one inventory
INVENTORY_DUR_UNIT
DINT
0
Unit for "DURATION"
•
0x00 = time [ms]
•
0x01 = inventories
•
0x02 = number of "Observed" events
LOCK-TAG-
BANK_ACTION
DINT
0
Lock-Action (see "EPC Specification")
LOCK-TAG-BANK_MASK
DINT
0
Lock-Mask (see "EPC Specification")
9.6.4
Commands
The structure of the commands with Rockwell controllers is identical to the structure with S7
controllers. You will find a description of the commands in the section "Commands
(Page 142)".