Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
264
Configuration Manual, 03/2018, C79000-G8976-C386-06
Parameter
Parameter
Type
Values
Description
value_id
Decimal value
0...9
0...4294967295
Unique command identifier
value_resultCode Decimal value
0...9
0...65535
Identification number of the error
You will find a list of possible return
codes in the following table.
value_name
Text
--
Textual description of the error
You will find descriptions of the prob-
lems in the following table.
value_cause
Text
--
Brief description of the cause of the
negative reply.
List of possible result codes
Result code
Name
Description
hex
dec
0x00 0
NO_ERROR
Positive reply, command processed suc-
cessfully.
0x13 19
ERROR_MEMORY_OVERRUN
Access outside the addressed memory
area.
0x1A 26
ERROR_TAG_LOCKED
The transponder to which data is meant to
be written or which should be deactivated is
locked.
0x91 145
ERROR_NO_ASWER_FROM_TAG
The transponder is not responding.
0x92 146
ERROR_WRONG_PASSWORD
The password you entered is incorrect.
Access to the transponder was denied.
0x93 147
ERROR_VERIFY_TAG_FAILED
Verification of the transponder failed.
0x94 148
ERROR_TAG_UNSPECIFIED
General transponder error.
0x95 149
ERROR_TAG_INSUFFICIENT_
POWER
There is not enough transponder power.
0x22 34
ERROR_TOO_MANY_TAGS
There are too many transponders in the
antenna field.
0xA1 161
ERROR_NO_TAG
There is no transponder with the relevant
EPC-ID in the antenna field.
0xA2 162
ERROR_NO_DATA
The requested data is not available.
0xA3 163
ERROR_INVALID_CRC
Bad checksum
0xA5 165
ERROR_NO_FREQUENCY
No radio channel activated.
0xA6 166
ERROR_NO_CARRIER
No carrier signal activated.
0xA7 167
ERROR_MORE_THAN_ONE_
TAG_IN_FIELD
There is more than one transponder in the
antenna field.
0xA8 168
ERROR_AIR_PROTOCOL_
UNSPECIFIED
General radio protocol error
0x41 65
ERROR_POWER_SUPPLY
Fault in power supply.