Using via Digital Data Communication
------------------------------------------------------------------------------------
76
Acknowledge Message
When a normal command is received, return “OK”. When an abnormal command is received, return “Error”.
Settings can be set, via command, so that no return is received when normal.
(When receiving QUERY commands, the response message becomes the Acknowledge Message.)
ZX Standard Command Details
IEEE488.2 Common Command
This section explains about the commands which conform to IEEE488.2 Common Command.
Common Command List
Command Name
Summary
Command Type
*IDN
Requests device information
QUERY Only
*RST
Resets set parameters
SET Only
*IDN
:Identification Query
Function:Retrieves device information (Name of Manufacturer, Name of Model, Software Version)
Format:*IDN?
Type:QUERY command only
Response:Name of Manufacturer, Name of Model, Software Version
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・
Sequence operation in progress
<Ex.>
*IDN?
TAKASAGO,ZX-S-400LN,1.00
*RST
: Reset
Function:Resets set parameters (Factory Default Settings)
Format:*RST
Type:SET command only
No parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・
Sequence operation in progress
<Ex.>
*RST
Summary of Contents for ZX-S-1600LAN
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...