T3PS Series Programming Manual
102
:SYSTem:COMMunicate:LAN:DNS
Set
Query
Description
Sets or queries the DNS address.
Note
The setting will only be valid after the power has been
cycled.
Syntax
Query Syntax
:SYSTem:COMMunicate:LAN:DNS <string>
:SYSTem:COMMunicate:LAN:DNS?
Parameter/Return <string>
DNS in string format ( “mask”)
Applicable ASCII characters: 20H to 7EH
Example
SYST:COMM:LAN:DNS “172.16.1.252”
SYST:REB
Sets the DNS to 172.16.1.252 reboot the unit to
active the setting.
:SYSTem:COMMunicate:RLSTate
Set
Query
Description
Enables or disables local/remote state of the
instrument.
Syntax
Query Syntax
:SYSTem:COMMunicate:RLSTate
{LOCal|REMote|RWLock}
:SYSTem:COMMunicate:RLSTate?
Parameter/Return
parameter
LOCal
All keys are valid. This instrument is
controlled by the front panel controls.
REMote
All keys are invalid, except for the [local]
key and the ability to turn the output off.
RWLock
All keys are invalid. The instrument can
only be controlled remotely.
Example
:SYST:COMM:RLST LOCAL
Sets the operating mode to local.