176
Query Syntax
SOURce[1|2]:SWEep:TIME? {<seconds>|
MINimum|MAXimum}
Return Parameter <NR3>
Returns sweep time in seconds.
Example
SOUR1:SWE:TIME?
+2.0000E+01
Returns the sweep time (20 seconds).
8-14-9. SOURce[1|2]:SWEep:SOURce
Set
Query
Description
Sets or queries the trigger source as immediate (internal),
external or manual. Immediate (internal) is the default trigger
source. IMMediate will constantly output a swept waveform.
EXTernal will output a swept waveform after each external
trigger pulse. Manual will ouput a swept waveform after the
trigger softkey is pressed.
Note
If the APPLy command was used to create the waveform
shape, the source is automatically set to IMMediate.
The *OPC/*OPC? command/query can be used to signal the
end of the sweep.
Syntax
SOURce[1|2]: SWEep:SOURce {IMMediate|EXTernal|
MANual}
Example
SOUR1: SWE:SOUR EXT
Sets the sweep source to external.
Query Syntax
SOURce[1|2]: SWEep:SOURce?
Return Parameter IMM
Immediate
EXT
External
MANual
Manual
Example
SOUR1:SWE:SOUR?
IMM
The sweep source is set to immediate.