Mar-07-2016 DI-50AN6 320 DS (NZ303)_UL_March 2016
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Page 9
Main Programming Mode
Calibration Modes for Input and Output
Code 1 – Display Configuration
Code 2 – CH1 Measurement Task & Sampling Rate
Code 3 – CH1 Post Processing & Serial Mode Functions
Code 4 – CH2 Measurement Task & Sampling Rate
Code 5 – CH3 Functions
Code 6 – CH4 Functions
Code 7 – Result Processing
Code 8 – Data Logging & Print Mode
Code 9 – Functions for Digital Input Pins
[CAL]
[Cod_1]
[Cod_2]
[Cod_3]
[Cod_4]
[Cod_5]
[
Cod_6]
[Cod_7]
[Cod_8]
[Cod_9]
Display Brightness
[bri]
The meter’s programming codes are divided into
two modes: the
main programming mode
, and the
setpoint programming mode
(See diagram below).
Each mode is accessible from the operational display.
Main Programming Mode
The main programming mode provides access to pro-
gram all meter functions, except setpoints.
Setpoint Programming Mode
The setpoint programming mode provides access to
program all setpoint and relay functions.
Code 10 – Bargraph Setup
[Cod10]
Code 10 applies to Tiger 320 Series meters with bargraph
displays only. See user manuals for DI-50EB51, DI-50TB51,
FI-B101D50E, and FI-B101D50T.
P
P
P
P
P
P
P
P
P
P
P
P
P
Setpoint Programming Mode
Setpoint 1
[SP_1]
Setpoint Activation Values Mode
Setpoint 2
[SP_2]
Setpoint 3
[SP_3]
Setpoint 4
[SP_4]
Setpoint 5
[SP_5]
Setpoint 6
[SP_6]
Enter these menus to adjust
SP activation values
Setpoint & Relay Control Settings Mode
P
P
P
P
P
Setpoint 1
[SPC_1]
Setpoint 2
[SPC_2]
Setpoint 3
[SPC_3]
Setpoint 4
[SPC_4]
Setpoint 5
[SPC_5]
Setpoint 6
[SPC_6]
Enter these menus to
configure SP control values
P
P
P
P
P
P
The
Setpoint and
Relay Control
Settings
diagram
on Pages 34 and
35 shows the
three digit config-
uration settings
that are applied
individually to
each setpoint.
See Page 33 for
an example proce-
dure to configure a
setpoint for simple
relay functions.
Front Panel Programming Codes
To enter or exit the Main Programming
Mode, press
P
and
at the same time
To enter or exit the Setpoint
Programming Mode, press
P
and
at the same time
Programming Tip
The easiest and fastest way to configure
the Tiger 320 is to use a PC with the free
downloadable configuration utility program.
To save a new setpoint
configuration setting and
return to the operational
display at any point,
press the
P
button
once.
Then press the
P
and
button at the same
time to exit.
Save SP Settings & Exit
To save a new main pro-
gramming mode configura-
tion setting and return to
the operational display at
any point, press the
P
button once.
Then press the
P
and
button at the same time
to exit.
Save Code Settings & Exit
Programming Tip
Programming Tip