Parameterization and configuration
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 102 of 131
TR - ECE - BA - DGB - 0089 - 04
02/03/2016
Overview of operating parameters
see note on page 92
Parameter
Data type
Byte
Not supported!
Format
Description
Count direction
bit
9
Short Diagnostics
bit
9
Commissioning diagnostics
bit
9
Teach-In function
unsigned8
10
X
Total measuring range
unsigned32 11
– 14
Revolutions numerator
unsigned32 15
– 18
Revolutions denominator
unsigned16 19
– 20
Code SSI-Interface
unsigned8
21
X
Code PROFIBUS-Interface
unsigned8
22
Preset 1
unsigned32 23
– 26
X
Preset 2
unsigned32 27
– 30
X
Lower limit switch
unsigned32 31
– 34
Upper limit switch
unsigned32 35
– 38
Data bits SSI-Interface
unsigned8
39
X
Bit coded operating parameters
DDLM_Set_Prm
Byte
9
Bit
7
– 0
Data
2
7
– 2
0
x = default setting
Bit Definition
= 0
= 1
Page
0
Count direction
ascending position values
for clockwise rotation
X
ascending position
values counter-
clockwise rotation
1
Short Diagnostics
yes
no
X
2
Commissioning
diagnostics
switched off
X
switched on