— 30 —
Example 3.
Turn off the ON rule with number 1 at channel A (defined at Example 2):
YD:SWA1 ON NEVER
The command without parameters or with the rule type only, returns the current settings.
Example 4.
Get the settings of the ON rule with number 1 at channel D (defined at Example 1):
YD:SWD1 ON
Example 5.
Program the Device to manage the ballast tank system shown in Figure 1. When tank 2’s level
(connected to channel D) is less than 20% (for 10 seconds or more), turn on the pump until the level in tank
2 is more than 70%. When the level in tank 1 (connected to channel A) is less than 20%, turn on the pump
in another direction (switch the polarity of reversible pump).
YD:SWA1 ON <20 10 0 1
YD:SWA1 OFF <20 10 0 2
YD:SWA2 ON <20 10 0 3
YD:SWA2 OFF >70 10 0 3
YD:SWD1 ON <20 10 0 2
YD:SWD1 OFF <20 10 0 1
YD:SWD2 ON <20 10 0 3
YD:SWD2 OFF >70 10 0 3