28
* Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299, and any Emergency Command enabled User).
** Features 30, 31 & 32 should be used with External DC Power unless feature is used for short a duration or infrequently. Sustained closure of
remote input or relay will drain batteries. Scheduled events and their associated audit trail entries will not occur during sustained closure of
remote input.
NOTE:
Enter
;
6
7
;
0
0
0
:
to delete all Relay Features added by Function 67 (identical to
Function 68).
*** Feature 24, "One Time Access for Group 3 Users", allows the creation of multiple 'one time only' User Codes. When activated, an entry by a
Group 3 User allows entry only once, then user becomes disabled.
Note:
When the User Code is entered for the first time and access is grant-
ed, the Event Log will read "Entry" followed by "User Disabled". If the User Code is entered a second time, access will be denied, and the Event
Log will read "User Denied Access".
To Enable the Feature:
Enter Program Mode and enter the key sequence
;
6
7
;
2
4
:
.
To assign the se-
lected User Codes to Group 3:
For example, to assign User Number 15 to Group 3, press:
;
3
5
;
1
5
;
3
:
.
†
Emergency Commands are disabled until a download from DL-Windows is performed. If a Function 67 or 68 (Clear Relay) is performed,
Emergency Commands are turned off.
†
†
Upon initial power up of the lock, options 39, 45 and 47 are enabled. A subsequent profile download from DL-Windows will enable 38, 39, and
45 through 48.
Ambush Function
1.
Connect relay to a device able to properly monitor dry contacts for an
Ambush
condition.
2.
Program the relay for
Ambush Tripped
using Program Function 67(10) above.
3.
Set the Ambush Code using Program Function 66.
4.
When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds.
Notes:
The Ambush Code defaults to
99
. An error will sound if you try to program a new User Code starting with the Ambush Code.
Programming Functions (cont'd)
;
6
7
;
[ _ _ ]
:
(Event
Number)
67. Add System Features (cont'd)
4
39.
Users are Disabled During Lockdown.
(Default = ON)
†
†
Basic Users (User Numbers 12 - 5000) are denied ac-
cess (passage through the door) during an Emergency.
43
Enable Sounder on Emergency.
(Default = OFF) Integral sounder beeps for 30 seconds while in Emergency.
44
Enable Inside Emergency Indicator.
(Requires inside housing with light bar). Pulses inside red LED while in
Emergency.
Note:
Enabling this option deletes all other relay outputs.
45
Activate Local Emergency: Keypad initiates Local Emergency Commands.
(Default = ON). Initiating an
Emergency command directly from the lock's keypad places only that lock into an Emergency state; the Emergency
command is not sent to other locks in the system.
46
Activate Global Emergency: Keypad initiates Global Emergency Commands.
(Default = OFF). Initiating an
Emergency command directly from the lock's keypad immediately sends the Emergency command to all other locks
in the system, then places the local lock into an Emergency state
†
†
.
47
Activate Local Emergency: Keyfob initiates Local Emergency Commands.
(Default = ON). Initiating an
Emergency command from a Wireless Remote Release (for example model RR-4BKEYFOB
Wireless Remote Re-
lease
) places only the paired lock into an Emergency state; the Emergency command is not sent to other locks in the
system.
†
†
.
48
Activate Global Emergency: Keyfob initiates Global Emergency.
(Default = OFF). Initiating an Emergency
command from a Wireless Remote Release (for example model RR-4BKEYFOB
Wireless Remote Release
) immedi-
ately sends the Emergency command to all other locks in the system, then places the paired lock into an Emergency
state
†
†
.
Door Status Monitoring
40.
Enable Door Monitoring.
(Default = OFF). If the Door Position Contacts remain open past the time set at
Function 68 "Door Ajar Trip Time" (default is 20 seconds), a Door Ajar event will be logged. The relay can also be
programmed for a Door Ajar event (see above feature 12). See "Door Ajar" in glossary.
41.
Sounder Alert on Door Ajar.
(Default = OFF). The integral sounder beeps when the Function 68 " Door Ajar
Trip Time" expires. Feature 40 must be set ("ON") for this sounder to operate (follows default Door Ajar Trip Time of
20 seconds unless programmed otherwise using Function 68).
42.
Forced Door Detection.
(Default = OFF). If a Forced Door is detected, i.e. the Door Position Contacts detect
the door was opened without first a valid credential unlocking the lock, or the door was opened without first the inside
lever turned (to activate an internal Lever Monitor Switch), a Forced Door event will be logged, the sounder will beep
for 3 seconds, and the red LED will turn on. The relay can be programmed for a Forced Door event (see above fea-
ture 14). See "Forced Door" in glossary. Feature 40 must be set ("ON") to enable Forced Door Detection.