6.3.10 Command RS
<id>RS<parameter><CR>
Reset
Access:
Read / write
Description:
Through the command RS a reset of the microcontroller is carried out.
The cause for the last reset is output without stating a parameter. Here,
the output occurs in the form of strings (see the following table), which are
lined up in a row, separated by spaces.
String
Description
PORF
Power On Reset Flag.
EXTRF
External Reset Flag.
BORF
Brownout Reset Flag.
WDRF
Watchdog Reset Flag.
PDIRF
Programming/Debug Interface Reset Flag.
SRF
Software Reset Flag.
SDRF
Spike Detector Reset Flag.
Parameter description:
1
Watchdog reset
2
Software reset
Value range:
1 / 2
Initial value:
-
6.3.11 Command SH
<id>SH<parameter><CR>
Station height
Access:
Read / write
Description:
The command is used to select the altitude at the location where the
Weather Station is installed.
This value is used to calculate the relative air pressure.
Height is specified in metres.
If the set parameter is 3001, the relative air pressure with elevation is
calculated from the GPS data.
Parameter description:
Height above MSL in metres
0...3000:
Station height in metres (the basis for calculation of the
relative air pressure)
3001:
The parameter SH is disregarded (calculation of the
relative air pressure is based on the height from the GPS
data)
Value range:
0...3001