PROGRAMMING STRINGS
5
3
3 PROGRAMMING
STRINGS
3.1 DEFINITIONS
Common definitions for each parameter are:
Depth (parameter depth)
Parameter depth indicates if the parameter is made up of a vector of values or a single value
(e.g.
Gain
parameter has depth > 1 since we have one
Gain
value for each recipe allowed;
Operating Mode
parameter has depth =1).
Depth must be specified when preparing the escape programming string.
Example:
Image Acquisition Setting #3
enable/disable.
Label:
Image Acquisition Setting
Escape Sequence
<ESC> a
#n
[selection]
Type (parameter type)
Parameter type is essential in order to decide the features of the serial command used to set
its new value. Types are:
Type 0
: Integer
(numeric)
Type 1
: Enumerative
Type 2
: String
Type 3
: Bit
Field
Type 4
:
At Least One
Label
Information available in the Parameters window of the VisiSet™ configuration tool.
The other definitions change according to the parameter type.
Integer (Type = 0)
Range
Minimum and maximum values allowed for the parameter.
Default
Default value (integer).