Page 15
Door/Window Sensor Advanced User Manual
Compatible Command Classes
Command Class
Notes
Notification V4 (71)
If Configuration Parameter 3 is set to 00, the Door/Window Sensor sends
a Notification Report to the main controller whenever the door is opened
and closed and also when tamper events are detected. Two different
Notification Types are used to achieve this.
Returned Value: 00 00 00 FF XX XX 00 00
V1 Alarm Type: 00
(Unsupported)
V1 Alarm Level: 00
(Unsupported)
Reserved: 00
(Reserved)
Notification Status: FF
(Unsolicited Reporting is Enabled)
Notification Type:
Door—06
(Access Control)
Tamper—07
(Home Security)
Event:
Door Open—16
(Window/Door is Open)
Door Closed—17
(Window/Door is Closed)
Tamper Detected—03
(Tampering, Product Covering Removed)
No Tamper Detected—00
(Event Inactive)
Sequence/Reserved/Event Parameters Length: 00
Notification Event Parameters: 00
(No Event Parameters)
Multilevel Sensor (31)
The Door/Window Sensor monitors ambient temperature levels and
reports this data to the main controller using the Multilevel Sensor
command class if Configuration Parameter 04 is set to 01 (this is off by
default.) Configuration Parameter 05 is used to “offset” the reported value
(add or deduct a static number from the reported value) and Configura-
tion Parameter 06 switches between Celsius and Fahrenheit.
Returned Value: 01 XX XX
Sensor Type: 01
(Temperature)
Precision/Scale/Size:
Celsius—01
(Precision = 000; Scale = 00; Size = 001)
Fahrenheit—09
(Precision = 000; Scale = 01; Size = 001)
Sensor Data: 00 ~ FF
(0 ~ 255 in Degrees Fahrenheit or Celsius)
Configuration V1 (70) See ““Configuration” Command Class Parameters” on page 16.
Table 6 - Command Classes Continued