Description of CANopen-Interface
HYDAC ELECTRONIC GMBH
07.10.2010
Mat. No. 669824
Page 56 of 63
9.13 Object 6507h: Profile and software version
This object contains in the 1st 16 bits the profile version which is implemented in the
measuring system. It is combined to a revision number and an index.
e.g.: Profile
version: 3.2
Binary code:
0000 0011 0000 0010
Hexadecimal:
3
2
The 2nd 16 bits contain the software version which is implemented in the measuring
system. Only the last 4 digits are available.
e.g.: Software
version:
01.04
Binary code:
0000 0001 0000 0010
Hexadecimal:
01 04
The complete software version is contained in object 100Ah, see page 45.
Unsigned32
Profile version
Software version
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
7
to 2
0
2
15
to 2
8
9.14 Object 6508h: Operating time
This object is not supported.
The operating time function is not used the operating time value is set to the
maximum value (FF FF FF FF h).
9.15 Object 650Ah: Modul identification
The sub-indices 1- 3 contains information manufacturer specific settings.
9.16 Object 650Bh: Serial number
This object contains the serial number of the device. It is equivalent to object 1018h
sub index 4.
9.17 Object 650Ch: Offsetwert
This object contains the offset value, which is calculated by preset function. The
offset value will be save and can be read from the measure system.
Index
Sub index
Comment
Type
650Ch 0
Highest sub-index supported
Unsigned8
1
Offset value
Signed32