48
48
7.42 ENTRY AMOUNT CONTROL PROGRAMMING
By this programming it is possible to define the value with which a registered amount
can finish ; with the same programming it can be defined moreover from which of last the
three digits of the amount (unit, tens and hundred, or second decimal. first decimal and unit)
must be activated the control on the format of the same amount.
In other words, by this programming it's possible to define if the ECR can accept final
amounts with whichever digit (Eg.: 156.73) or if the amounts allowed must obligatorily finish
for zero (Eg.: 156.70 or 156,00 or 150,00) or for five, fifty or five hundred (Eg.: 156.75 or
156.50 or 155,00).
Like evidenced in the above examples and like already indicated, it will be possible
to define if the amounts can end with a number whichever or must end for zero or can end
for zero or for five ; this definition can have effect on the units (or second decimal), the units
and the tens (or first and second decimal) or on the units, the tens and the hundreds (or first
decimal, second decimal and unit).
P
(63)
X/time
(AB)
Sub Total
#/NS
KEY
A : definition of the digit from which must begin the amount control format
0 = no control (default)
1 = control on the last digit of amount
2 = control on penultimate digit of amount
3 = control on antepenultimate digit of amount
B : amount format allowed (0 or 5)
0 = the defined digit can be only zero
5 = the defined digit can be zero or five
Examples: if AB = 10, all the amounts with the last digit different from zero will
generate an error on the ECR.
If AB = 35, all the amounts with last the three digits different from
"500" or "000" will generate an error on the ECR.
7.43
HALLO
LOGO
SELECTION
The J3500, beyond to the LOGO Personalizable (STORE LOGO) that it can be loaded
via PC by a graphical image (File) in Bitmap format, can use also 50 LOGOs already
residents and that can be select for direct printing.
It will be possible, after to have established the printing of the Hallo LOGO by the
Status System 2.G,H to define, by choosing from the list of LOGO available printed here
below, which Hallo LOGO will have to be printed from the ECR.
The procedure for the Hallo LOGO to print selection is following :
P
(66)
X/time
(NN)
Sub Total
#/NS
KEY
NN = Hallo LOGO to be printed (from 01 to 50, see below list)
Note: The HALLO Logo number 50 is programmable via PC, so it'll be possible to upload
by the Personal Computer a BitMap file (with correct size) an Hallo Logo
prechosen by the customer.
Summary of Contents for J3500E