54
PARAMETER DEFINITIONS—PPO Support Specification
8.2.3 Operation mode read/write
Read/write of the operation mode can be performed from the master.
8.2.4 Set frequency read
The frequency set to the inverter can be read from the master.
8.2.5 Terminal input read
The setting of the No. 2 terminal can be read.
8.2.6 Inverter reset
The inverter can be reset from the master.
• The inverter maintains the resetting status while reset is requested.
• When Pr. 75
≠
"0, 2, 14, 16", reset is enabled only during an inverter error.
PNU
Item
Data Definition
Data Type
P3
Operation mode read/write
External
: 10
H
PU
: 11
H
(Pr. 79 = "6")
NET
: 14
H
Us16
PNU
Item
Data Definition
Data Type
P4.1
Set frequency (RAM) read
Set frequency (RAM) is read.
AUs16
P4.2
Set frequency (E
2
PROM) read
Set frequency (E
2
PROM) is read.
AUs16
PNU
Item
Data Definition
Data Type
P5
No. 2 terminal input value read
No. 2 terminal input value (%) is read.
Us16
PNU
Item
Data Definition
Data Type
P6
Inverter reset
The inverter is reset after the data was written to the
master.
Us16